🚨 CriticalBosch RexrothPower Supply⚠️ Professional Repair Required
E7925

DC Link Overvoltage

The DC link capacitor bank voltage has exceeded safe operating limits, typically above 450VDC, indicating failure of voltage regulation circuits. This fault directly threatens connected equipment and requires immediate shutdown to prevent catastrophic component damage.

Quick Reference

Error Code

E7925

Severity

Critical

Equipment

Power Supply

Manufacturer

Bosch Rexroth

Observable Symptoms6 indicators
#1

Red overvoltage fault LED solid with accompanying audible alarm beeper at 1kHz

#2

DC link voltage reads 465-520VDC measured across main filter capacitors C1/C2

#3

All connected drives and controllers in emergency stop mode with F0010 overvoltage codes

#4

Visible arcing or corona discharge at high voltage connection points under low light

#5

Main contactor K1 chattering due to coil voltage exceeding 110% of rating

#6

Power supply case temperature elevated to 75-80°C when normal operating range is 45-55°C

Root Cause AnalysisMost common first
Most Likely

Shorted brake chopper IGBT Q5 allowing uncontrolled voltage buildup across DC link

90%
Common

Failed overvoltage protection circuit with damaged voltage comparator IC LM311

70%
Possible

Defective main switching transformer T1 with turn ratio shifted from 3:1 to 2.5:1

50%
Less Common

Open brake resistor R20 preventing energy dissipation during regenerative conditions

35%
Less Common

Lightning surge damage to MOV surge suppressors MOV1-MOV3 in input protection circuit

20%
Less Common

Failed DC link capacitor C1 with internal short causing resonant voltage doubling effect

20%
Step-by-Step Repair Procedure7 steps — safe checks first
Repair Progress Tracker0 / 7 steps
1

Immediately implement emergency lockout/tagout and evacuate personnel from 10-foot radius around equipment

2

Allow 30-minute cooldown period before approaching equipment wearing appropriate PPE including face shield

3

Use insulated hot stick to discharge DC link through 5kΩ 100W ceramic resistor bank

4

Measure brake chopper IGBT Q5 collector-emitter voltage with high voltage differential probe

5

Test overvoltage comparator circuit reference voltage - should be 4.50V ±1% at pin 3 of LM311

6

Replace failed brake chopper IGBT, gate driver board, and overvoltage protection components per service manual

7

Perform comprehensive system checkout with oscilloscope monitoring transient response during simulated fault conditions

⚠️

Safety First: Always isolate power and follow LOTO (Lockout/Tagout) procedures before working on electrical components. If unsure, contact a certified repair technician.

Affected Equipment Models
HNF01.1AHVE02.2PSU25.361HVR02.2HCS02.1E
🔔

Get fault code alerts for Bosch Rexroth equipment

Weekly repair tips, new fault codes, maintenance guides — free.

Trusted Since 1994 · ISO Certified · 32+ Years