🔴 FaultBosch RexrothCNC Controller⚠️ Professional Repair Required
E7848

Bus Voltage High

The DC bus voltage in the servo drive system has exceeded the upper threshold limit, typically above 400VDC in a 380V system. This condition affects the servo amplifiers and spindle drives, causing protective shutdown to prevent component damage from overvoltage stress on capacitors and switching devices.

Quick Reference

Error Code

E7848

Severity

Fault

Equipment

CNC Controller

Manufacturer

Bosch Rexroth

Observable Symptoms6 indicators
#1

Red fault LED illuminated on servo amplifier display with voltage reading above 410VDC

#2

CNC control panel displays 'SERVO ALARM 401 - BUS OVERVOLTAGE' message

#3

All servo axes immediately stop with regenerative braking disabled

#4

Spindle motor decelerates uncontrolled without dynamic braking

#5

DC bus voltage meter reads 420-450VDC instead of normal 350-380VDC range

#6

Audible relay clicking from main contactor cycling on overvoltage protection

Root Cause AnalysisMost common first
Most Likely

Faulty regenerative braking resistor (>10% resistance increase) or open circuit in braking IGBT

90%
Common

AC input voltage fluctuation above 420VAC due to utility supply instability or transformer tap issues

70%
Possible

Defective DC bus capacitors with reduced capacitance below 80% of rated value causing voltage spikes

50%
Less Common

Malfunctioning voltage feedback circuit in servo amplifier with drift in reference voltage divider

35%
Less Common

Rapid deceleration programming without proper ramp rates overloading regenerative capacity

20%
Less Common

Failed surge suppression devices allowing transient overvoltages from switching operations

20%
Step-by-Step Repair Procedure7 steps — safe checks first
Repair Progress Tracker0 / 7 steps
1

Implement LOTO procedure - disconnect main power, verify zero energy state with multimeter on all circuits

2

Measure AC input voltage at main terminals - should be 380-400VAC, check all three phases for balance within 2%

3

Test regenerative braking resistor with ohmmeter - should read 27-33 ohms, replace if open or >35 ohms

4

Check DC bus capacitor bank with capacitance meter - replace if below 80% of rated value or ESR >0.5 ohms

5

Inspect and test braking IGBT module with multimeter diode test - replace if short circuit or open gate detected

6

Verify servo drive voltage sensing circuit calibration - adjust reference voltage to 2.50VDC ±0.02V if drifted

7

Power up system and monitor DC bus voltage under load - verify 350-380VDC range during normal operation and <400VDC during regeneration

⚠️

Safety First: Always isolate power and follow LOTO (Lockout/Tagout) procedures before working on electrical components. If unsure, contact a certified repair technician.

Affected Equipment Models
MTX CNCCKE R911279559IndraMotion MTXCKK R911306020MTX micro
🔔

Get fault code alerts for Bosch Rexroth equipment

Weekly repair tips, new fault codes, maintenance guides — free.

Trusted Since 1994 · ISO Certified · 32+ Years

Get Your Equipment
Back in Action — Fast

Send us your faulty industrial electronics. Our engineers will diagnose it and provide a detailed quote within 24 hours — with no obligation to proceed.

Free Evaluation

No obligation

48hr Turnaround

Fastest in India

🛡

6-Month Warranty

Every repair

No Fix, No Charge

Zero risk policy

📦

Pan-India Pickup

Doorstep service