Skip to main content
OPEN NOW
0s

0% of today's working hours elapsed

Office Hours (IST)

Mon – Fri9:00 AM – 6:00 PM
Saturday9:00 AM – 3:00 PM
SundayClosed
Track Repair →
ACS800 Specialists

ABB ACS800 Repair

Expert ABB ACS800 Direct Torque Control drive repair — 0.55kW to 5600kW, all cabinet configurations. AINT/RMIO/D2D board repair, IGBT module replacement. 48-hour turnaround. Pan India.

3,800+
ACS800s Repaired
98.7%
First-Fix Rate
48hrs
Avg Turnaround
6 mo
Warranty
Scroll

India's most experienced ABB ACS800 repair centre. With ACS800 DTC architecture expertise, BSM-series IGBT modules in stock, and 48-hour turnaround on most repair scopes, we return your high-performance drive to full operation — at a fraction of the cost of OEM replacement.

3,800+
ACS800s Repaired
98.7%
First-Fix Rate
48 hrs
Avg Turnaround
5,600 kW
Max Drive Rating
DTC
Control Algorithm
6 mo
Warranty
Overview

The ABB ACS800 is ABB's flagship high-performance drive, built around ABB's proprietary Direct Torque Control (DTC) algorithm — delivering precise torque and speed control without encoder feedback. Deployed extensively in Indian paper mills, steel plants, cement factories, mining operations, and crane systems, the ACS800 range spans from compact single drives (0.55kW) to multi-megawatt drive systems (5600kW). Common failure modes include IGBT module (BSM series) failure, AINT inverter board faults, RMIO control board degradation, D2D fiber optic adapter failure, and DC bus capacitor ageing. Synchronics has repaired over 3,800 ACS800 units and holds detailed knowledge of both the single-drive and multi-drive (RDCU + AINT) architectures.

IGBT Module Replacement (BSM Series)
BSM75GB120DN2, BSM100GB120DN2, BSM150GB120DN2 and equivalent-spec IGBT module replacement with heatsink re-mounting, thermal compound renewal, and gate characteristic verification.
AINT Inverter Control Board
AINT board (A5E00124754) component-level repair — gate pulse generation circuits, optocouplers, fiber optic transmit/receive, and current measurement interfaces.
RMIO Control Board Repair
RMIO (Rectifier Motor I/O) board repair covering DSP, FLASH memory, I/O interface circuits, DDCS communication, and analog measurement accuracy.
D2D Fiber Optic Adapter
Drive-to-Drive (D2D) fiber optic link adapter repair or replacement — plastic optical fiber, SFP transceivers, and DDCS communication protocol integrity restored.
APBU Splitter Board
APBU (Auxiliary Power Board Unit) and fiber optic splitter board repair — enables multi-AINT drive configurations in parallel inverter systems up to 5600kW.
DC Bus Capacitor Bank
Full ESR and capacitance testing of ACS800 DC bus electrolytic capacitor bank — replacement with matched high-grade capacitors, bus ripple testing under load.

Diagnosis Guide

Common ABB ACS800 Problems We Fix

Experiencing any of these symptoms? Our engineers have diagnosed and repaired thousands of these faults.

critical

Fault 2310 — Overcurrent

Symptom

Drive trips immediately at start or during acceleration, no motor output, possible blown pre-fuse

Common Cause

IGBT shoot-through failure, motor winding insulation breakdown, output cable short, load jam causing instantaneous current spike

high

Fault 7121 — Drive Overtemperature

Symptom

Drive trips after running for a period, temperature warning precedes trip, cooling fan audible or absent

Common Cause

Cooling fan failure, heat sink contamination, thermal compound dried, high ambient temperature, sustained overload operation

high

Fault 2320 — DC Overvoltage

Symptom

DC bus overvoltage trip during deceleration or coasting, possible on regenerative loads

Common Cause

Braking chopper or resistor fault, deceleration ramp too aggressive, drive mains voltage above rated limit

critical

Fault 3211 — Input Phase Loss

Symptom

Drive trips, DC bus voltage low, input rectifier output unbalanced

Common Cause

Input fuse blown (one phase), supply contactor fault, input choke connection loose, supply transformer issue

moderate

Fault 7010 — Panel Communication Loss

Symptom

CDP/CDP312R panel shows communication error, drive parameters inaccessible, panel display blank

Common Cause

CDP panel cable damaged, RMIO communication port fault, panel connector corrosion, firmware mismatch

high

Fault 4110 — Control Board Overtemperature

Symptom

RMIO or AINT board internal temperature alarm, drive derate or trip at high load

Common Cause

Cooling fan air not reaching control boards, internal duct blockage, high ambient, fan speed feedback fault

How It Works

Our ACS800 Repair Process

A systematic, schematic-driven repair process — from receipt to dispatch.

01
STEP 01

Receipt & Configuration Recording

ACS800 drive type, option codes, and firmware version recorded. CDP panel parameters downloaded where possible. Visual inspection for arc damage, contamination, burnt components on AINT and RMIO boards.

Option codes loggedParameters downloadedVisual check
02
STEP 02

IGBT and Power Stage Test

IGBT modules tested in-circuit — gate-emitter threshold, collector saturation voltage, and reverse diode characteristics measured. AINT board gate signals verified with oscilloscope on isolated supply.

In-circuit IGBT testGate waveformsIsolated supply
03
STEP 03

Board-Level Fault Isolation

RMIO and AINT boards separated and tested independently. Fiber optic D2D link signal levels measured. Fault is isolated to specific board and component before any replacement is made.

RMIO / AINT isolatedD2D signal test
04
STEP 04

Component Replacement

Failed IGBTs (BSM series), gate driver ICs, optocouplers, electrolytic capacitors, and passive components replaced from 2M+ inventory. AINT fiber optic transceivers replaced if D2D link is degraded.

BSM IGBTsFiber optic2M+ parts
05
STEP 05

DTC Configuration & Motor ID

RMIO firmware verified, motor nameplate data entered (Group 99), and Motor ID Run performed to calibrate DTC torque model. DDCS communication and I/O tested.

Motor ID RunDTC calibrationDDCS test
06
STEP 06

Load Test & Dispatch

Full load bank test at rated current with torque step response measured. Thermal imaging of IGBT modules and heatsink. 6-month warranty certificate and detailed repair report issued.

Load bankThermal imaging6-month warranty

Thorough Inspection

ACS800 Component Inspection Checklist

Every unit goes through a comprehensive inspection checklist before and after repair.

IGBT Power Module (BSM Series)

Gate-emitter threshold Vge(th) — all phases
Collector-emitter saturation Vce(sat)
Freewheeling diode forward voltage
Thermal compound condition and coverage
DC bus busbar torque and connection integrity

AINT Inverter Board (A5E00124754)

Gate drive supply voltages (±15V per phase)
Gate pulse timing and dead-time (oscilloscope)
Optocoupler Vf and switching speed
Fiber optic TX/RX power level (D2D link)
Current sensor (LTSR) output accuracy

RMIO Control Board

DSP power-up and boot sequence
FLASH/EEPROM parameter integrity
DDCS fiber optic link (APBA/RDCU)
Analog measurement accuracy (AI1–AI3)
Digital I/O isolation and relay contacts

D2D Fiber Optic Adapter

Plastic optical fiber continuity
TX optical power level (–15 to –5 dBm typical)
RX sensitivity and bit error rate
DDCS frame sync and data integrity
Adapter connector and mounting condition

DC Bus Capacitor Bank

Capacitance per cell vs rated value
ESR measurement at 100Hz
Bank voltage balance (parallel strings)
Pre-charge resistor and relay operation
Bus bar insulation and torque

Cooling Fan Assembly

Fan speed RPM via tachometer
Fan motor current draw
Fan bearing vibration and noise
Thermistor NTC resistance at ambient
Air inlet filter condition and airflow path

The Synchronics Advantage

Why Choose Us for ABB ACS800 Repair

DTC Architecture Expertise

We understand the ACS800 DTC motor model calibration process — Motor ID Run, flux reference tuning, and torque ripple verification. Repaired drives are not just electrically restored, they are re-calibrated for correct DTC operation.

Multi-Drive System Support

We repair ACS800 multi-drive systems including RDCU + AINT configurations, APBU splitter boards, and D2D fiber links — the complete high-power parallel inverter architecture.

48-Hour Turnaround

Most ACS800 single-drive repairs are completed within 48 hours. Large cabinet and multi-drive systems are assessed individually — we provide a realistic turnaround estimate with the repair quotation.

Troubleshooting

ABB ACS800 Fault Codes We Fix

Seeing one of these error codes? We diagnose and repair the root cause.

2310
Meaning

Overcurrent — motor current exceeds 3.5× drive rated current

Possible Cause

IGBT failure, motor winding short, cable insulation breakdown, load jam

2320
Meaning

DC overvoltage — DC bus exceeds maximum safe level

Possible Cause

Braking chopper fault, deceleration too fast, regenerative load energy, mains overvoltage

2330
Meaning

DC undervoltage — DC bus below minimum threshold

Possible Cause

Mains phase loss, input fuse blown, capacitor bank degradation, charging circuit fault

2340
Meaning

Short circuit — output short circuit detected

Possible Cause

IGBT shoot-through, motor cable phase-to-phase fault, output terminal short

3211
Meaning

Input phase loss — one input phase missing

Possible Cause

Input fuse blown, contactor fault, supply cable loose connection

4110
Meaning

Control board overtemperature — AINT/RMIO temperature limit

Possible Cause

Cooling fan fault, internal air duct blockage, high ambient temperature

7010
Meaning

Panel communication loss — CDP panel not responding

Possible Cause

CDP cable fault, RMIO communication port damage, panel connector corrosion

7121
Meaning

Drive overtemperature — heatsink temperature above limit

Possible Cause

Fan failure, blocked heatsink, IGBT thermal resistance increased, overload operation

ACS800 faults are logged in the fault history register (Group 06) with time stamps. When sending your drive for repair, note the fault codes and operating conditions — this significantly speeds up our diagnosis.

Industries Served

Where ABB ACS800s Are Used

Paper & Pulp Mills

Winder drives, headbox pumps, press section, coater drives — demanding dynamic torque control

Steel & Metal Processing

Rolling mill drives, coiler/uncoiler, tension stands, run-out tables requiring precise DTC

Mining & Minerals

Conveyor belt drives, crusher feeders, hoist drives, ball mill, SAG mill — high-inertia loads

Cement Plants

Kiln fan drives, raw mill, cement mill, bucket elevator, belt feeder applications

Cranes & Material Handling

Bridge cranes, overhead cranes, port equipment, hoist drives requiring four-quadrant operation

Marine & Offshore

Thruster drives, pump drives, HVAC fans on marine and offshore platforms

Trusted Brands

Brands We Service

Component-level repair for all major manufacturers

FAQ

Frequently Asked Questions

Yes. We repair the complete ACS800 multi-drive architecture — RDCU rectifier control unit, AINT inverter boards, APBU fiber splitter, and D2D adapter. Each board is tested independently and as a system before dispatch.

Fault 2310 at startup is a strong indicator of IGBT module failure, but it can also be caused by a fault on the AINT gate driver board (which may have been damaged by the IGBT failure). We test both the IGBT module and AINT board gate circuits before replacing either component.

Yes. If motor nameplate data is provided, we perform the Motor ID Run in our facility using a test motor of appropriate rating to calibrate the DTC torque model. For large drives above 200kW, we set motor data parameters manually per ABB procedure and recommend a site Motor ID Run on the actual motor.

Yes. We stock common BSM series modules (BSM75GB120DN2, BSM100GB120DN2, BSM150GB120DN2, BSM200GB120DN2) for fast turnaround. For less common high-power modules, we source from verified suppliers — we will include expected lead time in the repair quotation.

All repaired ACS800 drives carry a written 6-month warranty. If the same fault recurs within the warranty period, repair is free of charge. The warranty covers the repaired components and workmanship — not damage from external causes such as input power surges or motor faults.

ABB ACS800 Drive Repair Services Across India

Synchronics provides specialist ABB ACS800 Direct Torque Control drive repair for industrial customers across India — from our facility in Vadodara, Gujarat, with pan-India pickup and delivery. We repair ACS800 drives for paper mills in Vapi, steel plants in Surat, cement factories in Rajasthan, mines in Jharkhand and Odisha, and crane operators in Mumbai and JNPT — covering every major industrial region.

The ABB ACS800 family spans a remarkable power range from 0.55kW single-phase drives to 5600kW multi-drive cabinet systems. Our engineers are trained on the DTC motor model architecture, AINT/RMIO board circuitry, and D2D fiber optic communication system that make ACS800 unique. With a 2M+ component inventory that includes BSM IGBT modules, AINT board components, and fiber optic adapters, we deliver the fastest ACS800 repair turnaround available in India.

Trusted Since 1994 · ISO Certified · 32+ Years

Get Your Equipment
Back in Action — Fast

Send us your faulty industrial electronics. Our engineers will diagnose it and provide a detailed quote within 24 hours — with no obligation to proceed.

Free Evaluation

No obligation

48hr Turnaround

Fastest in India

🛡

6-Month Warranty

Every repair

No Fix, No Charge

Zero risk policy

📦

Pan-India Pickup

Doorstep service