🔴 FaultSiemensServo Drive⚠️ Professional Repair Required
F0364

Position Feedback Loss

Position feedback loss indicates complete failure of the encoder system providing rotor position and velocity information to the servo control loop. This critical fault causes immediate drive shutdown as the system cannot maintain accurate positioning control required for servo operation. The fault typically affects encoder interface circuits, communication protocols, or encoder hardware components.

Quick Reference

Error Code

F0364

Severity

Fault

Equipment

Servo Drive

Manufacturer

Siemens

Observable Symptoms6 indicators
#1

Servo drive immediately displays F031 encoder fault with drive status changing to fault mode and motor disable

#2

Drive HMI shows position feedback value frozen at last known position or reading constant zero

#3

Encoder interface board error LED illuminated solid red with normal operation LED extinguished

#4

Oscilloscope shows no pulse signals on encoder A/B channels or missing differential signal pairs A+/A-/B+/B-

#5

Motor position drift occurs with drive enabled but no feedback - motor may creep or oscillate uncontrollably

#6

Drive current consumption increases to maximum rated value as control loop attempts feedback compensation

Root Cause AnalysisMost common first
Most Likely

Encoder cable damage including conductor breaks, shield degradation, or connector pin corrosion/looseness

90%
Common

Rotary encoder internal failure affecting optical disc, LED light source, or photodetector assemblies

70%
Possible

Encoder interface board failure including differential receiver ICs, signal conditioning circuits, or power supplies

50%
Less Common

Encoder mounting mechanical failure causing air gap changes, misalignment, or coupling disconnection

35%
Less Common

Electrical noise interference from welding, VFDs, or switching power supplies corrupting encoder signals

20%
Less Common

Encoder contamination from coolant, metal particles, or environmental debris blocking optical sensors

20%
Step-by-Step Repair Procedure7 steps — safe checks first
Repair Progress Tracker0 / 7 steps
1

Implement LOTO safety isolation - remove all power and verify de-energized state using appropriate test instruments

2

Inspect encoder cable for physical damage, measure conductor continuity, and verify proper connector seating and pin contact

3

Test encoder power supply at interface board - verify +5VDC ±0.25V and +/-15VDC ±0.5V where applicable

4

Replace encoder cable assembly if continuity tests fail or if shield resistance exceeds 1 ohm to ground

5

Verify encoder mechanical mounting integrity, coupling alignment, and proper shaft connection without binding

6

Replace encoder interface board if power supplies correct but no encoder signals present at board outputs

7

Commission new encoder by performing drive offset calibration procedure and verify accurate position tracking during test moves

⚠️

Safety First: Always isolate power and follow LOTO (Lockout/Tagout) procedures before working on electrical components. If unsure, contact a certified repair technician.

Affected Equipment Models
SINAMICS S120SINAMICS V90SINAMICS S210SINAMICS G120DSINAMICS S110
🔔

Get fault code alerts for Siemens equipment

Weekly repair tips, new fault codes, maintenance guides — free.

Trusted Since 1994 · ISO Certified · 32+ Years