🔴 FaultMitsubishiPower Supply⚠️ Professional Repair Required
024

Bus Voltage Low

The DC bus voltage has dropped below the minimum operating threshold, typically below 350VDC for 400V systems. This condition indicates problems with the PFC boost stage or input power quality affecting the ability to maintain proper DC voltage levels.

Quick Reference

Error Code

024

Severity

Fault

Equipment

Power Supply

Manufacturer

Mitsubishi

Observable Symptoms6 indicators
#1

Yellow undervoltage LED flashing at 2Hz rate on power supply status panel

#2

DC bus voltage measurement reads 280-340VDC when specification requires 385-405VDC

#3

Connected equipment shutting down intermittently with low voltage protection active

#4

Input current drawn increases by 15-20% above nameplate rating during operation

#5

PFC inductor L1 producing audible 120Hz magnetostriction noise

#6

Output ripple voltage increases to 8-12V peak-peak from normal 2-3V measurement

Root Cause AnalysisMost common first
Most Likely

Defective PFC boost inductor L1 with partial winding short reducing inductance by 30-40%

90%
Common

Failed PFC switching MOSFET Q1 with increased on-resistance above 0.8Ω specification

70%
Possible

Degraded electrolytic capacitors C3/C4 in DC bus with ESR exceeding 0.5Ω at 120Hz

50%
Less Common

Input line voltage sagging below 440VAC during peak load conditions

35%
Less Common

Open PFC boost diode D2 preventing proper energy transfer to DC bus

20%
Less Common

Contaminated PFC control IC UC3854 with moisture causing erratic switching operation

20%
Step-by-Step Repair Procedure7 steps — safe checks first
Repair Progress Tracker0 / 7 steps
1

Execute lockout/tagout procedure and verify all energy sources isolated with appropriate test equipment

2

Use insulated tools to safely discharge DC bus through appropriate load bank resistor

3

Measure AC input voltage at terminals L1, L2, L3 during load conditions with true-RMS meter

4

Test PFC inductor L1 inductance value with LCR meter - should read 1.2mH ±10% at 1kHz

5

Check PFC MOSFET Q1 with curve tracer for gate threshold voltage 2-4V and on-resistance specification

6

Replace failed PFC components including inductor, MOSFET, and boost diode with exact OEM parts

7

Commission system with gradual load application while monitoring DC bus voltage regulation and ripple content

⚠️

Safety First: Always isolate power and follow LOTO (Lockout/Tagout) procedures before working on electrical components. If unsure, contact a certified repair technician.

Affected Equipment Models
S8JCS8VSS8JXS82KDRT2-ID16MLQ61P
🔔

Get fault code alerts for Mitsubishi equipment

Weekly repair tips, new fault codes, maintenance guides — free.

Trusted Since 1994 · ISO Certified · 32+ Years