🔴 FaultDanfossPower Supply⚠️ Professional Repair Required
AL70

Temperature Fault

The internal temperature monitoring circuit has detected excessive heat buildup within the power supply enclosure, typically exceeding 70°C ambient or 85°C at critical components. This triggers protective shutdown to prevent component damage and indicates insufficient cooling or increased power dissipation from failing components.

Quick Reference

Error Code

AL70

Severity

Fault

Equipment

Power Supply

Manufacturer

Danfoss

Observable Symptoms6 indicators
#1

Red temperature fault LED flashing in 2-second intervals on control board

#2

Power supply output shuts down after 30-60 seconds of operation under load

#3

Cooling fan runs continuously at maximum RPM but inadequate airflow measured

#4

Heat sink temperature exceeds 80°C when measured with infrared thermometer

#5

Electrolytic capacitor tops showing signs of thermal stress or bulging

#6

Burnt smell emanating from power supply enclosure during operation

Root Cause AnalysisMost common first
Most Likely

Blocked air intake filters reducing cooling airflow by more than 40%

90%
Common

Failed cooling fan bearing causing reduced RPM below 2000 RPM specification

70%
Possible

Thermal interface material degradation between semiconductors and heat sinks

50%
Less Common

High ESR output filter capacitors generating excessive I²R heating

35%
Less Common

Power MOSFET or diode junction temperature rise due to increased forward voltage drop

20%
Less Common

Ambient temperature exceeding maximum specified operating range of 40°C

20%
Step-by-Step Repair Procedure7 steps — safe checks first
Repair Progress Tracker0 / 7 steps
1

Execute lockout/tagout procedure and allow 30-minute cooldown period before inspection

2

Clean all air intake filters and verify unrestricted airflow through enclosure

3

Test cooling fan current draw and RPM, replace if below 80% of rated specification

4

Remove and clean all heat sinks, apply fresh thermal compound to all semiconductor mounting surfaces

5

Measure ESR of all electrolytic capacitors, replace any exceeding 100 milliohms

6

Check forward voltage drop of all power diodes and MOSFETs under rated current

7

Install power supply with proper clearances and verify ambient temperature <35°C during full-load operation

⚠️

Safety First: Always isolate power and follow LOTO (Lockout/Tagout) procedures before working on electrical components. If unsure, contact a certified repair technician.

Affected Equipment Models
MBS 3000MBS 4750MBS 33MBS 5100
🔔

Get fault code alerts for Danfoss equipment

Weekly repair tips, new fault codes, maintenance guides — free.

Trusted Since 1994 · ISO Certified · 32+ Years

Get Your Equipment
Back in Action — Fast

Send us your faulty industrial electronics. Our engineers will diagnose it and provide a detailed quote within 24 hours — with no obligation to proceed.

Free Evaluation

No obligation

48hr Turnaround

Fastest in India

🛡

6-Month Warranty

Every repair

No Fix, No Charge

Zero risk policy

📦

Pan-India Pickup

Doorstep service